Products

Analytical

Applied Analytics

Applied Analytics, Inc. is a global supplier of online analysis equipment serving the oil, natural gas, chemical, and pharmaceutical industries. For over 20 years, AAI has provided efficient and economical solutions to the most challenging industrial applications using UV-Vis and NIR spectroscopy AAI's flagship OMA-300 process analyzer and TLG-837 tail gas analyzer help comprise the comprehensive product line that suits many analytical requirements.
Applied Analytics was incorporated in 1994 and manufactured in the USA.

OMA Series Process Analyzer

OMA Series Process Analyzer

The OMA is an industrial device which measures a high-resolution absorbance spectrum in a continuously drawn sample from a liquid or gas process stream.
OMA-300 Standard Analyzer
The default version of the OMA Process Analyzer is provided in a wall-mounted enclosure. The system is highly customizable including options for enclosures, wetted materials, and hazardous area classifications.
Chemical Concentrations:
The OMA can simultaneously monitor up to 5 chemicals in the sample stream. All analytes must have distinct absorbance curves in the 200-1100nm UV-Vis/SW-NIR wavelength range to be measurable by the OMA.
Chemical Purity: By measuring a high-resolution transmittance spectrum, the OMA can very precisely detect impurities in the sample fluid by sudden changes in the spectral structure.
Physical Properties:
Various properties such as the heating value of a fuel or the octane of a gasoline blend can be

Specialized OMA Solutions:

  • Ammonia analyzer
  • BTX Analyzer
  • Chlorine Analyzer
  • Clean in Place Analyzer
  • Color Analyzer
  • Continuous Emission Analyzer
  • H2S Analyzer
  • Metallons Analyzer
  • NOx Analyzer
  • Odorant Analyzer

Eexp

Eexp

Eexp systems are purged and pressurized using a certified air-purging device. This method ensures that toxic/explosive gas is not allowed to accumulate inside the enclosure, and is ideal when instrument air is available.

OMA-206P

OMA0-206P

Portable Analyzer
The portable version of the OMA Process Analyzer is housed in an ultra-rugged suitcase enclosure, so you can bring analytics from site to site with confidence.

Tail Gas Analyzer

Tail Gas Analyzer

The TLG-837 continuously measures the H2S / SO2 ratio in Claus process tail gas to provide an always-reliable air demand signal.

Mix-2000 Digital Mixer

Mix-2000 Digital Mixer

The automated gas mixing system from Applied Analytics utilizes cutting-edge mass flow controllers to achieve the precision and repeatability required for demanding applications like research and instrument calibration.

MICROSPEC MCP-200 Infrared Analyzer

MICROSPEC MCP-200 Infrared Analyzer

The MCP-200 is a real-time concentration monitor for chemical species that absorb IR radiation. Engineered to be compact and modular, the MCP-200 excels as both a rugged standalone and an integrated component

Eexd

Eexd

Eexd systems are contained within certified explosion-proof cast-aluminum enclosures. This method is more practical if the installation is remote or utilities are unreliable.

OMA-406R

OMA-406R

Rackmount Analyzer
The rackmount version of the OMA is designed for easy integration in analyzer shelters and laboratory settings. The system fits a standard 19" rack.

OMA-300 H2S Analyzer

OMA-300 H2S Analyzer

The OMA H2S analyzer continuously measures H2S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the power of collateral data to establish excellent dynamic range and sustain accuracy in the presence of cross-interfering species. With an ultra-safe fiber optic design and solid state build, this system is simple to install and relentlessly reliable.

Features: Continuously measures H2S concentrations in a liquid or gas process stream Up to 4 additional software benches for additional analytes (e.g. SO2 , R-SH) Totally solid state build with no moving parts - modern design for low maintenance Ultra-safe fiber optic design with dedicated sample flow cell - no toxic/corrosive sample fluid in analyzer enclosure.
Decades of field-proven performance in the world's harshest industrial environment

Headspace Sample Conditioners

Headspace Sample Conditioners

When a liquid is too opaque or dirty to transmit a light signal, direct optical analysis may be impossible. In this case, the composition of the liquid can be measured by heating the sample and effective analytical solution for opaque liquids, including: crude oil, dirty wastewater and amine solution. analyzing the vaporous 'headspace' gas. The headspace sampling system design uses Henry's Law to provide a highly

M&C

The ‘M&C TechGroup Sales Service’ company employs international sales professionals in Europe and the ‘M&C TechGroup MechParts GmbH’ is specialised in the manufacturing of mechanical components. The ‘M&C TechGroup Real Estate GmbH’ incorporates, manages and maintains all international real estate properties owned by M&C. The group is financially and legally in all regards independent, and takes responsibility for defining its own corporate policy.
M&C products and special systems provide excellent service and reliability; this is proven by our product quality and capability to provide customer specific solutions for over 30 different current industries and applications.
This is the reason why over 5,000 customers worldwide, from small, highly skilled engineering companies to well-known corporations, have confidence in our products again and again.
Our customers benefit from a number of significant competitive advantages

SP180 Series

SP180 Series

CEMS applications
Self-regulating 180 °C
Low temperature alarm
75 mm filter element ceramic, glass fiber, Teflon, SS
Calibration gas included
New insulation with special silicone (T°, UV, ….)
Cost-favorable version
Available for Ex zone 1 + 2
Available for marine application

SP2200, SP2500, SP2600

SP2200, SP2500, SP2600

Dusty applications (cement, steel, ...)
Controlled 180 °C
Filter element 140 cm2or 300 cm2
Automatic blowback filter and/or prefilter
Integrated isolation valve for high efficiency
Calibration gas
Extractable prefilter/tube
Many options available

SP3000

SP3000

Explosion-proof zones 1, 2, 20, 21 and 22
Self-regulating 120 °C/140 °C
Or controlled up to 180 °C (230 °C for Ex Zone 2)
T°controller inside or outside the zone
Ex certificate for the whole probe
Many options available-Calibration gas-Automatic blowback-Diesel/Tars filter-Integrated ball valve

Prefilters

Prefilters

Dust load > 10 g/m3
Up to 1000 °C
Chemical/corrosion resistance
PTFE, SS, Hastelloy, ceramic 1 m max.
Extension tube if needed
Protective plates
Heated adapter for high T°and dust load

Self-regulating

Self-regulating

120 °C max. (65 W/m)
Heater traced along the line
T°depending on ambient conditions
SS or Teflon tube
Replaceable tube (Teflon)
Ø 4/6 mm to 10/12 mm
100 m max.
Single tube

Ex-versions

Ex-versions

Available for Ex zone 1
Self-regulating up to 120 °C
T°controlled up to 200 °C
SS or Teflon tube
Replaceable tube (Teflon)
Ø 4/6mm to 8/10mm

Deep Cooler EC30 Series

Deep Cooler EC30 Series

Compressor and Peltier combination
Dew point adjustable from -20 °C to -30 °C
Temperature alarm
PVDF, PTFE, glass, SS
1 x 250 Nl/h
Peristaltic pumps built in
Options available (Pt100, fan, …)
Application: Aerosols reduction due to acid content

VC Series

VC Series

Pre-coolers to relieve main cooling system
Ambient air dew point
PVDF, PTFE, glass, SS
1 x 250 Nl/h to 2 x 250 Nl/h
Applications:-High humidity-Without heated line-Electrochemical cells

Peltier ECP Series

Peltier ECP Series

Peltier coolers
Adjustable dew point +2 °C to +15 °C
Temperature alarm
PVDF, PTFE, glass, SS
1 x 150 Nl/h to 1 x 500 Nl/h
Options available (Pt100 for T°display, …)

Drainer AD Series

Drainer AD Series

Automatic drainers
Automatic drainers/ separators
High drain capacity (Nl/h)
Sample gas under pressure: 1-19 bar max.
PVDF, PTFE, glass, SS
SS version suitable for Ex zones 1, 2

Vessels TG, TK

Vessels TG, TK

Collecting vessels
High resistance to corrosion
Liquid level alarm
Downstream cooler and/or SR25
Pressure: 0.2-2.2 bar
PVC, PTFE, glass, FPM
Capacity: 1 -10 liters

Heated Filters

Heated Filters

350 °C max.
PTFE, glass, ceramic, SS
0.05 µm to 250 µm
5 bar max.
Diesel/tars filter
Low temperature alarm

Adsorption Filters FP

Adsorption Filters FP

Wide variety of adsorption material
Capacity: 65 to 190 cm3
5 bar max.

Bellows Pumps

Bellows Pumps

Bellows technique
5 Nl/min to 10 Nl/min
All parts made of PTFE (against corrosion)
Liquid and acid-resistant
Bypass needle valve available
Pump head rotation 180 °C
2 x Sample In and 2 x Sample Out
Sample T°+140 °C max.
Less maintenance
Available for Ex zone 1

NOx Converters CG-2

NOx Converters CG-2

With 2 types of catalysts (C or SS) for higher conversion efficiency (> 95% with new catalyst)
T°oven: 350 °C or 660 °C
Low temperature alarm
19” or wall mounting
Easy catalyst replacement
Options available-Catalyst bypass with solenoid valves-Complete heated version for ‘hot’ systems and in case of high NO2content

Paramagnetic Oxygen Transmitter/Analyzer

Paramagnetic Oxygen Transmitter/Analyzer

Using the Magneto-dynamic technology
Small dead volume (2 ml) for faster response time
Low drift and low cross-sensitivity against other components
Most selective and reliable method for O2measuring in a linear range of 0 to 100 % vol.
High resistance against corrosion
Different materials available (e.g. cell for chlorine application)
No maintenance or replacement of the cell when used correctly
Analog output and status alarm
Possibility of single transmitter type PMA05
Universal Touch Screen interface/Intuitive graphic user interface similar to smartphones
Available for Ex zone 1/EN 14181 for the portable version/SIL EN 61508

SP2000 Series

SP2000 Series

CEMS & Process applications
Controlled 180 °C
150 mm filter element
Many options available-Teflon, Titanium-Calibration gas-Diesel/Tars filter-320°
C-Steam-heated-Integrated ball valve withactuator (blowback/cal. gas)

SP2200, SP2500, SP2600

SP2200, SP2500, SP2600

Dilution Series
Dilution ratios from 10:1 up to 500:1
Heated up to 320 °C
Dilution probe (filter) or dilution panel
Independent of process temperature
Easy operation and maintenance (without tools)
Replaceable eductornozzles
Dilution air preheater
Many options available

Standard Tubes

Standard Tubes

Up to 1800 °C
Chemical/corrosion resistance
PVDF, PTFE, SS, Kanthal, Hastelloy, Inconel, ceramic, aluminiumoxide 2.5 m max.
Standard G 3/4”
Special demister tube SP32 for wet applications

Heated Tubes

Heated Tubes

To avoid condensation in the probe tube
Up to 320 °C
Low temperature alarm
SS, Hastelloy
Fix or portable 2 m max.
Available for Ex zone 2
Possibility of extension tubes or prefilters

T°controlled

T°controlled

250 °C max. (120 W/m)
Heater coiled around the line
T°independent of ambient conditions
SS or Teflon tube
Replaceable tube (Teflon)
Ø 4/6mm to 10/12mm
30 m max. per circuit
Single tube

Compressor EC Series

Compressor EC Series

Compressor coolers
Adjustable dew point +2 °C to +7 °C
Temperature alarm
PVDF, PTFE, glass, SS
1 x 250 Nl/h to 4 x 250 Nl/h
T°display
Peristaltic pumps built in
Options available (Pt100 for external control, fan, …)

EX Series

EX Series

Compressor coolers
Explosion-proof zones 1, 2
Adjustable dew point +2 °C to +7 °C
Temperature alarm
PVDF, PTFE, glass, SS
1 x 250 Nl/h to 4 x 250 Nl/h
T°display
Option: Ex peristaltic pumps

EX Series

EX Series

Compressor coolers
Explosion-proof zones 1, 2
Adjustable dew point +2 °C to +7 °C
Temperature alarm
PVDF, PTFE, glass, SS
1 x 250 Nl/h to 4 x 250 Nl/h
T°display
Option: Ex peristaltic pumps

LC, LT Jacket Coolers

LC, LT Jacket Coolers

Gas and liquid cooler using coiled or bundle of tubes technology
Coolant needed (water, air, …)
Petrochemical & process applications
10 bar max.
700 Nl/h max.
Special requests on demand

Peristaltic Pumps SR25

Peristaltic Pumps SR25

Automatic removal
Capacity: 0.3 Nl/h
Sample gas pressure:0.2-2.2 bar
Suitable for Ex zones 1, 2
Version for H2O2(or equivalent) dispensing
Options available (wall mounting, housing, acid-resistant, …)

Universal Filters FP, FT

Universal Filters FP, FT

Modular construction
PVDF, PTFE, SS, ceramic
0.05 µm to 250 µm
250 bar max.
Liquid sensor and pressure measurement possible

Front Panel Filters FPF

Front Panel Filters FPF

PVC, PVDF, glass fiber
0.1 µm and 0.3 µm
4 bar max.
Liquid sensor

Diaphragm Pumps

Diaphragm Pumps

3 Nl/min to 17 Nl/min
PVDF, PTFE, Viton or all parts made of PTFE (against corrosion)
Sample T°+80 °C max.
Many options available-Housing-Bypass needle valve-Double diaphragm safety system
Heated pump 180 °C (10 Nl/min) with T°alarm
Available for Ex zone 1

Injectors Series GIP

Injectors Series GIP

3.5 Nl/min to 13.5 Nl/min
SS, glass, FPM
Corrosion-resistant
Sample and ambient temperature +180 °C max.
Maintenance-free

Air Generator BA

Air Generator BA

Supply of 4 bar and 3 Nl/min max. of air (adjustable)
Air quality:-CnHm< 10 ppb-Dew point < -10 °C-Dust and oil-free
Status alarm
Possibility of internal compressor
Easy catalysts replacement

Advanced

Founded in 1993, Advanced Holdings Ltd. (the “Group”), a Mainboard-listed company on the Singapore Exchange, is a global engineering science organization that designs, manufactures and markets a diverse range of innovative products and solutions to the Oil & Gas, Petrochemicals & Chemicals industries to make operations safer, cleaner and more efficient.
Advanced has manufacturing facilities and offices in more than 11 countries, including the USA, UK, France, Germany, Saudi Arabia, UAE, China and Singapore. This global presence allows Advanced to work more closely with its customers while providing comprehensive engineering services.

advanced